Quick start reference – Rola-Chem 554000 ORP/pH Digital Controller User Manual

Page 2

Advertising
background image

QUICK START REFERENCE

Use this section for reference - please read all safety instructions and

appropriate manual sections for installation and operation instructions.

• Do NOT add chemicals to feeders until all start-up operations are completed.

• Manually adjust and balance pool/spa to acceptable levels and verify using DPD test kit prior

to start-up. Automation should be used to maintain chemical levels, not to balance a pool/spa
that is out of acceptable chemical ranges.


On/Off:
- Press the mode button to turn the unit on. Note: ‘FLOW’ light must illuminate.
- Press and hold the mode button to turn the unit off.
- “OFF” will be displayed in the windows

To Operate:
- Press and release the mode button until the “AUTO” LED is lit.
- Unit will now operate in the factory preset settings:
- Set levels: ORP = 650 mV, pH = 7.4
- Feed times: 0.6 second feed with a 5 minute delay
- Limits: ORP; 900 hi, 100 low, pH; 8.0 hi, 7.0 low

To Change Settings:
Note: Press and release the mode button until the desired ORP or pH LED is lit.
Once the settings are changed, they will remain at those settings until they are changed again.

- Set level: press the Set Level button until the desired set point is reached. Release the button.
- Feed time: press the Feed Time button until the desired feed time is reached.
Release the button.
The numbers represent the seconds of feed time (all with 5 minute delays).
Range is 0.6 to 900 sec. (15 min.). Constant feed is ‘con’. Factory setting is 0.6 sec.
- Hi alert: press the Hi Alert button until the desired level is reached. Release the button
- Low alert: press the Low Alert button until the desired level is reached. Release the button.

Manual Feed:
- Press and release the mode button to light the LED associated with the desired feeder to be

manually fed, ORP or pH.

- Press the “feed once” button. The desired feeder will go through one “set feed” time cycle.
There is no manual feed option when the unit is in constant feed.

Other
: See the appropriate manual sections for--
- setting the time out feature
- calibrating the pH sensor
- changing dip switches (pH/ORP interlock, feeder time out, acid/base, and lockout).

Rola-Chem Digital Controller PN 554102 6/01/2012 Page: 2 of 20