2.2 Specifications

ORP & pH Ranges ORP

pH .

Display:

0 to 995 mv.

6.8 to 8.4

Control:

400 mv to 900 mv 7.0 to 8.0

(5 mv increments)

Factory default:

650 mv

7.4

Input Power
120 Volts AC, 50/60 HZ, 3 wire grounded power cord.

Combined load not to exceed 15 amps.

GFCI source required

Output Power

120 Volts AC, 50/60 HZ, 5 amps (fused) for both ORP and pH

Two 3-wire grounded power receptacles

Terminal strip for hardwire applications (included)


Displays:

ORP and pH – red digital
Power and flow indicator - LED
Alert indicator & Feed indicator- LED (ORP & pH)
Mode indicator- LED (pH ,ORP , Auto)


NOTE- feed lamps flash during the feed time and are on constant during the delay time of the
feed cycle.

O

perating Temperature: 40 to 120° F


Selectable Features
+ ORP and pH settings + High and low ORP and pH alerts + ORP and pH feed/delay times
+ Manual feed

+ pH calibration

+

Acid/base

feed

+ Keypad Lockout

+ Adjustable time-out + ORP and pH Interlock

+ Reset

Features and Options
+ Flow switch input

+ Individually fused outputs + 120 vac transformer


2.3 Description of Controls

1. WATER FLOW LAMP

Illuminates bright when water flow is indicated. Also indicates that power is on.