0 appendix, 2 typical system installations – Rola-Chem RC554P pH Digital Controller User Manual

Page 12

Advertising
background image

Rola-Chem Digital Controller

PN 554236 02/17/2014

Page: 12 of 12

8.0 Appendix

8.1 WATER CHEMISTRY RANGES

(These ranges are in accordance with suggested NSPI
Standards for swimming pools.)

pH: 7.4 -7.6

Alkalinity: Approx. 80-120 ppm ** (parts per million)
Higher levels may be acceptable in areas where it
naturally occurs in the local water supply.
Consult a pool professional in your area.
Cyanuric Acid:
0-50 ppm.

Maintain at 30 ppm or less for best probe life.*

TDS (Total Dissolved Solids): 300 - 2000 ppm
Calcium Hardness: 200-400 ppm
Free Chlorine:
1.0 - 3.0 ppm (> 700 millivolts ORP)

*20-30 ppm of cyanuric acid provides approx. 95% of the shielding effect for chlorine.
**When using tri-chlor, recommended alkalinity is 95-125 ppm.

8.2 Typical System Installations

pH

CONTROLLER

CHLORINE
GENERATOR
CONTROLS

CELL

SYSTEM USING ELECTROLYTIC CHLORINE GENERATOR

pH CONTROL WITH ACID PUMP

MANIFOLD

** FLOWSWITCH

EARTH
GROUND

*** OPTIONAL FILTER TO

HELP KEEP MANIFOLD

AND PROBES CLEAR OF

DEBRIS.

*SAFETY FLOWSWITCH FOR

PROTECTION OF HEATER AND

TO ENSURE DILUTION OF
CHEMICAL INTO POOL.

**SAFETY FLOWSWITCH TO ENSURE
CIRCULATION TO CONTROL PROBES

AND INDICATOR THAT POOL

CIRCULATION IS OCCURRING.

ACID

EARTH
GROUND

HEATER

FILTER

POOL
PUMP

WATER

FROM
POOL

*FLOWSWITCH

***FILTER

WATER
TO

POOL

PUMP

ELECTRICAL
OUTLET
CONTROLLED BY
CIRCULATION
SYSTEM

Advertising