Suggested tools, Required material, Identification – Badger Meter Gas Meter Endpoints User Manual

Page 3: Suggested tools 3, Required material 3, Identification 3

Advertising
background image

SUGGESTED TOOLS

VOM Multi-Meter (Analog)

59987-001

Coax Stripper

59989-001

Wire Cutting Pliers

59991-001

Wire Stripper

59993-001

Parallel Pliers

59983-001

TORX® #T-10 Driver

1/4" - 3/4" Vari-Bit (Newark 81N2636)

3/32" Transfer Punch

3/16" Transfer Punch

Double-Side Tape (3M 442PC)

62658-003

Table 1: Suggested tools

REQUIRED MATERIAL

OTEE:

N

Numbers in the first column correspond to the parts shown in

Figure 3 on page 4

1

*Gasket (1)

62838-001

Parts marked with *
are included in the
Installation Kit

2

Outer cover

3

*TORX screws (4)

31820-026

4

*Gel connectors (2)

59761-001

5

*Ear clamp (1)

59759-001

*Ear clamp (1)

59759-002

Transmitter wire (Belden 9802) not shown

59604-003

Table 2: Required materials

IDENTIFICATION

The Badger Meter Gas Recordall® Transmitter (Gas-RT) is available in two configurations: Clockwise Operation (CW) and

Counterclockwise Operation (CCW), as identified on the frame (looking toward the index), with the markings CW or CCW for

both configurations The Gas-RT should be installed so that the wire port is at the lower edge See

Figure 1

Red/Black: Used with TRACE® Remote and Pit Transponders, Itron® ERT® Remote and Pit Transponders, and ORION® Pit and

Remote Transponders

Identification-

clockwise operation

Identification-

counterclockwise

operation

Figure 1: CW & CCW operation identification

The Gas-RT is available for a wide variety of gas meters See

"Gas-RT Application Data" on page 6

for the correct unit

Before proceeding with installation, be certain the meter type conforms to the rotation for your Gas-RT and the proper Gas-RT

configuration, indicated above, has been supplied for the application

Installation Manual

Page 3

July 2014

Advertising