6 Test the entire installation including the Gas-RT and remote unit in accordance with the manufacturer's instructions
7 Carefully fold the wires and splices to fit and then slide the Gas-RT cover into place until it snaps

OTEE:

N

The cover is designed for tamper protection and cannot be removed without damage To remove the cover, press the

blade of a screwdriver into the indention in the cover; doing so releases the hatch

Slide cover into

grooves until it

snaps into place

Punch out indent

to release catch for

cover removal

Fold wires to fit

under cover

Figure 7: Cover placement

GAS-RT APPLICATION DATA

Sensus®/Rockwell®/Equimeter®

Index style #1

Index style #2

Index style #3

X

Y

Index

style

Index drive dial

rotation

1 465

1 020

#5

Clockwise

1 176

861

#4

Counterclockwise

1 503

773

#3

Counterclockwise

1 632

552

#2

Counterclockwise

966

594

#1

Clockwise

Index style #4

Index style #5

Recordall®, Gas Transmitter (Gas-RT)