WIRING GAS-RT

1 Feed the two-conductor shielded transmitter wires (Belden 9802) through the hole in the housing
2 Strip approximately 1-1/2 inch of outer insulation sheath from the cable using the 59989-001 Coax Stripping Tool Use

caution removing the outer sheath so that the inner signal wire insulation is not damaged See

Figure 4

Belden #9802 shielded

cable for direct burial

P/N 59604-003

Remove foil shield and cut

bare conductor flush with end

of outersheath

Figure 4: Cable stripping detail

3 Locate the bare conductor (shield drain) and cut it off flush with the end of the outer sheath This is a "floating ground" and

should never be terminated at the transmitter Unwrap and remove the foil shield flush with the end of the outer sheath

4 Place a strain relief clamp on the wire and secure it onto the outer sheath, approximately 1/8 inch from the end, by

crimping each "ear" alternatively with the wire cutting pliers See

Figure 5

1/8”

Ear clamp

P/N 59759-001

Figure 5: Strain relief

5 Connect the Gas-RT conductors to the remote cable conductors using the installation displacement gel-filled splices

(59761-001) provided in the installation kit Crimp the splices carefully and completely using a parallel jaw crimper, such as

the Badger Meter crimper (59983-001) Polarity must be observed when connecting the Gas-RT to the remote The black

conductor of the Gas-RT is to be terminated to the negative (–) conductor See

Figure 6

Gel splices

Observe polarity

black negative (-)

Strain relief

Figure 6: Gas-RT wiring

Installation Manual