Badger Meter ReadCenter User Manual

Page 19

Advertising
background image

Page 19

10-11

Installation & Operation Manual

Screen Layout for Other Reports

The middle section of the screen is blank. The right section shows report details.

Two text boxes are displayed in the bottom tool bar next to the Close button. The left is blank. The right contains

the number of records returned for the report selected.

Buttons

Show Record: Open the Account Records screen showing all of the information for the account being viewed.

Graph: (History report only) Open a screen showing usage calculations and a usage graph for meter readings shown.

Refer to "Graph" on page 20 for details.

File: Allow saving report results to a comma delimited file for import into Excel®. Refer to "File" on page 21 for details.

Preview: Open a screen with a preview of the report results that can be sent to a printer.

Apply: (Last Read report only) Write meter readings shown in the report to the Account Record for billing

purposes. Refer to "Apply Gateway Readings to the Customer Account Records" on page 26 for more information.

Report Definitions
Transmitter Alerts

Tamper*: The most current meter reading within the time period selected where a transmitter reported a tamper

condition. A tamper condition occurs when there is a cut or damaged wire.

Encoder Error (ADE)*: The most current meter reading within the time period selected where a transmitter

reports an error with the encoder. An error condition occurs when the encoder exhibits a temporary or

permanent failure to extract the current reading.

Reverse Flow (ADE)*: (Applies to Badger Meter GALAXY transmitters with an ADE only.) The most current meter

reading within the time period selected where a transmitter reported a reverse flow condition. The reverse flow

condition indicates when an ADE encoder has measured flow in the reverse direction, causing the current reading

to be lower than the previous recorded reading.

Leak*: The most current meter reading within the time period selected where a transmitter reported a potential

leak condition. A leak condition occurs when there is “continuous usage” over a 24-hour time frame.

- RTR: Badger Meter GALAXY transmitters with an RTR look at a 24-hour time period for 1 hour of non-usage.
- ADE: Badger Meter GALAXY transmitters with an ADE look at a 24-hour time period for 2 hours of non-usage.

Forced Read*: The most recent occurrence within the time period selected where a transmitter reported a meter

reading that was manually initiated. For a TR3 transmitter, this is done by a command from a handheld computer

connected to it via IR. For a TR2 transmitter, this is done by magnetic activation.

Reading Reports

Last Read: The most current meter reading within the time period selected.

No Read: The most current meter reading for transmitters that have not reported within the time period selected.

Usage: The most current meter reading, the lowest meter reading, and the difference between them within the

time period selected. Settings under the Preview Options tab allow you to select records to show when

previewing the report.

Not Advancing: The most current meter reading for transmitters where the meter reading did not change within

the time period selected.

History: All transmitters that have reported meter readings within the time period selected, along with the

individual meter readings collected within that time frame.

Installations (First Read): The first meter reading recorded for all transmitters. Time period selection is not used.

*Indicates alert conditions detected by GALAXY transmitters. Priority of Alerts: Tamper, Encoder Error, Reverse Flow, Leak,

Forced Read.

Advertising