Blue-White C-600P CHEM-FEED Diaphragm Pump User Manual

Page 2

Advertising
background image

TABLE OF CONTENTS

SECTION

HEADING

PAGE

1

Introduction

2

2

Specifications

2

3

Features

3

4

How to install the metering pump

3

4.1

Mount Location

4

Installation

5

4.2

Electrical connections

6

4.3

How to install the tubing and fittings

7

5

How to operate the metering pump

9

5.1

Adjusting the Pump Output - Standard Models

9

5.2

Adjusting the Pump Output - Fixed cycle timer Models

9

5.3

Measuring the pump’s output - volumetric test

10

6

How to maintain the metering pump

10

6.1

Routine inspection and cleaning

10

6.2

How to clean the metering pump

10

Exploded View (C-600HV)

11

Exploded View (C-600P)

13

1.0 Introduction

Thank you for purchasing the positive displacement metering pump.
The pump is designed to inject chemicals into piping systems.
All models are equipped with a top mounted mechanical flow rate
adjustment knob. Optional on/off cycling timers are available.

2.0 Specifications
Maximum Working Pressure

125 psig / 8.6 bar* (C-600P)
20 psig 1. 37 bar* (C-600HV)

o

o

Maximum Fluid Temperature

130 F / 54 C

Output Accuracy

+/- 10% of maximum

o

(water @ 70 F, 0 psig, and 5’ suction lift)

o

o

Ambient Temperature Range

14 to 110 F / -10 to 43 C

Enclosure

Zinc - Metal

Duty Cycle

Continuous

Maximum Viscosity

1,000 Centipoise

Maximum Suction Lift

up to 10 ft. water

Power Requirements

115V60Hz 45 Watts
220V50Hz 45 Watts
230V60Hz 45 Watts
24V60Hz 45 Watts

Dimensions

6-1/2” H x 6-1/2” W x 5-3/4” D (C-600P)
7”H x 6-3/4” W x 6-1/8” D (C-600HV)

Weight

8 lb.

**Depending on Model number