4.2

Electrical Connections

Be certain to connect the pump to the proper supply voltage.
Using the incorrect voltage will damage the pump and may result in
injury. The voltage requirement is printed on the pump serial label.

Note: When in doubt regarding your electrical installation,
contact a licensed electrician.

The metering pump is supplied with a junction box for field wiring.

JUNCTION BOX MODELS -To reduce the risk of electric shock,
be certain that a grounding conductor is connected to the green
grounding screw located in the junction box.

FIG. 4.5 WIRING DIAGRAM - STANDARD MODELS

AC
MOTOR

INPUT

VOLTAGE

115V 60Hz

HOT

LEADWIRE

NEUTRAL

LEADWIRE

GROUND

LEADWIRE

230V 60Hz

BLUE or YELLOW*

BLUE

BROWN

RED

GREEN

GREEN

GREEN

MOTOR LEADWIRES

Neutral

Hot

Ground (green)

Earth Ground (green)

Common

Hot

AC

Input

Power

220V 50Hz

BLACK or YELLOW*

BLACK or YELLOW*

* Yellow leadwire : thermally protected motor
Black or Blue leadwire: standard impedance protected motor

24V 60Hz

WHITE

GREEN

BLUE*

C-600

Page 6