Blue-White C-600P CHEM-FEED Diaphragm Pump User Manual

Page 3

Advertising
background image

*

Most C-600P Models. C-600HV has max pressure rating of 20 PSIG

4.0

How To Install the Metering Pump

Note: All diagrams are strictly for guideline purposes only. Always
consult an expert before installing the metering pump into specialized
systems.
The metering pump should be serviced by qualified persons only.

4.1

Mounting Location

Choose an area located near the chemical supply tank, chemical
injection point and electrical supply. Install the pump where it can be
easily serviced.

!

Mount the pump to a secure surface or wall using the enclosed

hardware. Wall mount to a solid surface only. Mounting to drywall with
anchors is not recommended.

!

Keep the outlet (discharge) tubing as short as possible. Longer tubing

increases the back pressure at the pump head.

!

Do not mount the pump directly over your chemical container.

Chemical fumes may damage the unit. Mount the pump off to the side
or at a lower level than the chemical container.

!

Mounting the pump lower than the chemical container will gravity feed

the chemical into the pump. This “flooded suction” installation can
reduce the time required to prime the pump. Install a shut-off valve,
pinch clamp or other means to halt the gravity feed to the pump during
servicing.

!

Your solution tank should be sturdy. Keep the tank covered to reduce

fumes.

!

Be sure your installation does not constitute a cross connection with the

drinking water supply. Check your local plumbing codes.

CAUTION: PROPER EYE AND SKIN PROTECTION MUST BE WORN

WHEN INSTALLING AND SERVICING THE PUMP

3.0 Features

!

Double-ball ceramic check valves.

!

PVDF (Kynar) valve assemblies.

!

Viton o-rings.

!

High outlet pressure capability of 125 PSIG.*

!

Easy access, side mounted mechanical feed rate adjustment.

!

Ball bearing supported motor drive shaft.

!

Permanently lubricated ball bearing motor.

!

27:1 adjustment turn down ratio.

!

Easy servicing.

!

Includes suction tube foot valve & strainer, suction tube weight, suction

tubing, discharge tubing and injection fitting with internal back-flow
check valve and mounting hardware.

CAUTION - This pump has been evaluated for use with water only.

*Depending on Model number