Blue-White CHEM-PRO C3 ProSeries Diaphragm Pump User Manual

Page 11

Advertising
background image

Page 11

Used to remotely start and stop pump using a dry contact closure signal.
When activated; CLOSE = START and OPEN = STOP.

Set to NO = Remote Start / Stop is disabled
Set to Yes = Remote Start / Stop is enabled

Can be used with external foot pedal, PLC, contact closure or other similar external devices.

Default setting = No (disabled)

Step 3

Press and release DOWN arrow to change setting to ‘YES.’
To change setting back to ‘NO’ press and release UP arrow.

Step 4

After you’ve made your selection, press and release START
| STOP button. This saves your setting.
You can now modify FVS setting (see next page) or you can
exit Setup by pressing and holding START | STOP button
for a few seconds until you return to Run screen.

Running pump with Remote Start / Stop enabled, ‘REMOTE’ icon will always be visible on lower left side of screen.
Pump will display ‘STBY’ (standby) if pump is in stop mode via contact closure signal. Please use caution in this mode, pump can
start at anytime. If you must perform maintenance to pump, press and release STOP button.

yes

0

yes

0

Step 2

Press and hold START | STOP button until ‘Remote’ icon
begins flashing.
Default setting ‘NO’ will also be visible when entering
remote start / stop setup.

Note: If ‘YES’ had been selected previously, then ‘YES’ will be
displayed on screen.

no

0

Remote

Icon

REMOTE

REMOTE

REMOTE

7.0

Set Remote Start / Stop

Step 1

Press and release STOP button

Note: Cannot enter programming mode while pump is running.

off

Chem-Pro

Chem-Pro

®

®

Press and release
Press DOWN arrow to decrease pump
speed (output) in Manual Operation.
To decrease value while in programming
mode.

6.0

How to Operate Chem-Pro® - Control Pad

Press and release
To prime pump (60 seconds) – See page 17

Press and hold
To enter programming mode.

Ÿ

Remote Start/Stop setup

Ÿ

FVS (flow verification sensor) setup

Press and release
To save setting while in programming mode.
To move to next selection while in programming mode.

Time-out - Chem-Pro® pumps have a time-out setting of approximately 20 seconds while in configuration menu. If built-in
timer exceeds 20 seconds without a button being pressed, then pump will exit configuration menu. Changes will only be
saved after START | STOP button is pressed and released.

Press and release
Press UP arrow to increase pump speed
(output) in Manual Operation.
To increase value while in programming
mode.

Press and release
To Stop pump at any time.

Press and release
To Start pump.
To begin listening (reacting) to external signal, such as Remote
Start/Stop.

Page 10

START

STOP

START

STOP

PRIME

START

STOP

Advertising
This manual is related to the following products: