Typical installation, Foot valve, 0 output versus pressure chem-pro chem-pro – Blue-White CHEM-PRO C3 ProSeries Diaphragm Pump User Manual

Page 22: Page 23, Page 22

Advertising
background image

Page 23

®

®

Typical Installation

Foot Valve

CHEM-PRO

TM

tm

CHEM-PRO

C3V | Diaphragm Metering Pump

Made in the USA

MODE

PRIME

Program

Minimum

Maximum

Blue-White Ind.

IP66

NEMA 4X

Suction Tubing

Injection /

Check Valve

Chemical Tank

Priming /
Degassing Tubing

Discharge Tubing

Page 22

15.0 Output Versus Pressure

Chem-Pro

Chem-Pro

0

25

5

10

15

20

Feed Rate US GPH

Small Diaphragm, Max 175 PSIg / 12 bar

Model: C2x2x1
166 RPM
Small Diaphragm
.060” Offset

0

25 (1.7)

50 (3.4)

75 (5.2)

100 (6.8)

125 (8.6)

150 (10.3)

PSIg (Bar)

Feed Rate LPH

95

18.9

37.9

56.8

75.7

0

25

5

10

15

20

Feed Rate US GPH

Small Diaphragm, Max 175 PSIg / 12 bar

Model: C2x2x3
166 RPM
Small Diaphragm
.040” Offset

0

25 (1.7)

50 (3.4)

75 (5.2)

100 (6.8)

125 (8.6)

150 (10.3)

PSIg (Bar)

Feed Rate LPH

95

18.9

37.9

56.8

75.7

175 (12.0)

175 (12.1)

15.1 C2 Output V. Pressure

14.2 C3 Output V. Pressure

175 (12.1)

0

25 (1.7)

50 (3.4)

75 (5.2)

100 (6.8)

125 (8.6)

150 (10.3)

0

50

10

20

30

40

Feed Rate US GPH

0

5

10

Feed Rate US GPH

15

20

25

Maximum 100 PSIg / 5.5 bar

Model: C3x2x2
130 RPM
.100 Stroke Length

PSIg (Bar)

Maximum 150 PSIg / 10.3 bar

Model: C3x2x1
130 RPM
.060 Stroke Length

175 (12.1)

0

25 (1.7)

50 (3.4)

75 (5.2)

100 (6.8)

125 (8.6)

150 (10.3)

PSIg (Bar)

Feed Rate LPH

95

18.9

37.9

56.8

75.7

Feed Rate LPH

95

18.9

37.9

56.8

75.7

0

25

5

10

15

20

Feed Rate US GPH

Large Diaphragm, Max 175 PSIg / 12 bar

Model: C2x2x2
166 RPM
Large Diaphragm
.060” Offset

0

25 (1.7)

50 (3.4)

75 (5.2)

100 (6.8)

125 (8.6)

150 (10.3)

PSIg (Bar)

Feed Rate LPH

95

18.9

37.9

56.8

75.7

175 (12.0)

Advertising
This manual is related to the following products: