Blue-White CHEM-PRO C3 ProSeries Diaphragm Pump User Manual

Page 12

Advertising
background image

Page 12

Page 13

Flow verification sensor sold separately.

Flow verification system is designed to stop pump in an event sensor does not detect flow during pump operation.
Indicating an empty chemical tank, clogged injection fitting, loose tubing connection, etc.

To allow pump to clear any gasses that may have accumulated over time, an alarm delay time value from 1 to 255
seconds must be programmed.

Note: An alarm delay of 000 seconds disables FVS system.

Step 3

Press and release START | STOP button to scroll through
menu until you see FVS icon.
If you pass FVS screen, continue to press and release
START | STOP button until FVS icon appears.

Step 4

FVS icon will appear for 1 second, followed by numbers.
These numbers indicate delay time setting for FVS.
Select a delay time in seconds. Delay time is amount of time
pump will wait to receive a pulse from sensor until an alarm
is triggered.
A delay time of 00 deactivates FVS feature.

FVS

0

00

0

Step 5

After you’ve made your selection, press and release START
| STOP button. This saves your setting.
Press and hold START | STOP button to exit Setup menu
and return to runtime screen.

Flow Verification Sensor is designed to give you two installation options.

Sensor can be installed:

!

Directly onto pumphead of Chem-Pro® pump, discharge side.

!

Anywhere on discharge side of Chem-Pro® pump.

Wiring for sensor can be connected directly to a Chem-Pro® pump. Pump will stop pumping if sensor detects no
flow. A relay will then close allowing for remote alarm indication or initiation of a back-up pump.

Install FVS Flow

Sensor - Flow Verification Sensor should be installed on inlet (suction) side of pump tube.

When installing directly onto pump 3/8” tube discharge fitting:

Sensor includes a PVC tubing insert, located inside sensors female thread connection, that is designed to
seal sensor onto pump tube adapter. Thread sensor onto pump tube until tubing insert is snug against pump
tube fitting - do not over-tighten.

SEC

7.1

Set FVS (flow verification system)

7.1

Set FVS (flow verification system) - Continued

Time-out - Chem-Pro pumps have a time-out setting of 20 seconds while in configuration menus. If built-in timer exceeds 20 seconds
without a button being pressed, then pump will exit configuration menu. Changes will only be saved after RIGHT arrow button is
pressed and released.

Step 1

Press and release STOP button

Note: Cannot enter programming mode while pump is in running.

off

Step 2

Press and hold START | STOP button until ‘Remote’ icon
begins flashing.
This indicates that you’ve entered Setup menu.

no

0

Remote

Icon

REMOTE

off

Sensor Model Number

Actual Working Range with

Chem-Pro® Pump

ML/Min

ML/Min

30-200

FV-100

30-300

Published Flow Range

50-900

FV-200

100-1000

100-1800

FV-300

200-2000

300-3000

FV-400

300-3000

500-5000

FV-500

500-5000

700-7000

FV-600

700-7000

Confirm FVS flow range - Flow Verification Sensor (FVS) will only function within its operating range. See chart
for available ranges.

NOTE: If pump output is less than 30 ml/min, sensor will not detect chemical and a signal will not be sent to
pump, resulting in an alarm condition.

NOTE: For low viscosity (water-like) fluids only. Consult factory if attempting to use with viscous fluids.

Chem-Pro

Chem-Pro

®

®

C3V | Diaphragm Metering Pump

Made in the USA

MODE

PRIME

Program

Minimum

Maximum

Blue-White Ind.

IP66

NEMA 4X

FVS

Sensor

Advertising