C-1100v, 2 input power connections, Page 5 typical installation – Blue-White C-1100 CHEM-FEED Diaphragm Pump User Manual

Page 5: Parts locator drawing

Advertising
background image

CAUTION: Proper eye and skin protection must be
worn when installing and servicing the pump.

CAUTION

ADJUST WHILE RUNNING

DISCHARGE LINES MAY BE

UNDER HIGH PRESSURE. USE
CARE TO PROTECT YOURSELF

WHEN DISCONNECTING.

MAX

MIN

1

2

3

4

5

6

7

8

9

LOOSEN THE LOCK SCREW

TURN KNOB TO DESIRED SETTING

RE-TIGHTEN THE LOCK SCREW

RUN

STANDBY

RUN

FIELD

DIGIT

MODE

PROGRAM

STAND-BY

PRIME

MINIMUM

MAXIMUM

INPUT MODES

1 - MANUAL

2 - 4-20mA

3 - 0-10VDC

4 - PULSE (Hz)

PROGRAM

RESET SERVICE

PRIME

DISPLAY

VARIABLE SPEED PUMP

% SPEED

VDC

SERVICE

ALARM

mA

Hz

Page 5

TYPICAL INSTALLATION

Suction

Tube

Chemical
Container
with cover

Discharge

Tube

Strainer

Ceramic Weight

Injection / Check valve
with 1/4” and 1/2” male
pipe threads.
Mount in upward position
to prevent trapped gasses
in the injection fitting.

Wall or shelf mount
away from the top of the
solution tank. Chemical
fumes can damage the
unit.

5.2 Input Power Connections

! Be certain to connect the pump to the proper supply voltage. Using the

incorrect voltage will damage the pump and may result in injury. The
voltage requirement is printed on the pump serial label.

! Removable resistors on the circuit board are factory preset for the correct

voltage. See page 7 Circuit Board Connections diagram for details.

! The pump is supplied with a ground wire conductor and a grounding type

attachment plug (power cord). To reduce the risk of electric shock, be
certain that the power cord is connected only to a properly grounded,
grounding type receptacle.
Note: When in doubt regarding your electrical installation, contact a
licensed electrician.

WARNING: Risk of electric shock.

PARTS LOCATOR DRAWING

®

J-Box

Control Cover

Motor Housing

Rear Cover

Pumphead

6

Slide Clamps*

CAUTION

ADJUST WHILE RUNNING

DISCHARGE LINES MAY BE

UNDER HIGH PRESSURE. USE

CARE TO PROTECT YOURSELF

WHEN DISCONNECTING.

MAX

MIN

1

2

3

4

5

6

7

8

9

LOOSEN THE LOCK SCREW

TURN KNOB TO DESIRED SETTING

RE-TIGHTEN THE LOCK SCREW

Adjustment knob

10

IN

. (254

MM

)

1
4

IN.

10

IN.

(267

MM

)

(159

MM

)

1

2

Control Panel

C-1100V

RUN

STANDBY

RUN

FIELD

DIGIT

MODE

PROGRAM

STAND-BY

PRIME

MINIMUM

MAXIMUM

INPUT MODES

1 - MANUAL

2 - 4-20mA

3 - 0-10VDC

4 - PULSE (Hz)

PROGRAM

RESET SERVICE

PRIME

DISPLAY

VARIABLE SPEED PUMP

% SPEED

VDC

SERVICE

ALARM

mA

Hz