C-1100v, 4 how to install the tubing and fittings, Page 8 – Blue-White C-1100 CHEM-FEED Diaphragm Pump User Manual

Page 8: Injection/check valve

Advertising
background image

Page 8

5.4 How To Install the Tubing and Fittings

! Inlet Tubing - Locate the inlet fitting of the pump head. Remove the tube

nut. Push the clear suction tubing through the tube nut and onto the fitting
barb. Hand tighten the tube nut to secure the tubing.

CAUTION: Proper eye and skin protection must be
worn when installing and servicing the pump.

! Footvalve/Strainer - Trim the inlet end

of the suction tubing so that the strainer
will rest approximately two inches from
the bottom of the solution tank. This will
prevent sediment from clogging the
strainer. Slip the ceramic weight over
the end of the suction tube. Press the
strainer’s barbed fitting into the end of
the tube. Secure the ceramic weight to
the strainer. Drop the strainer into the
solution tank.

! Injection/Check Valve Fitting

Installation - The Injection/Check valve
fitting is designed to install directly into
either 1/4” or 1/2” female pipe threads.
This fitting will require periodic
cleaning, especially when injecting
fluids that calcify such as sodium
hypochlorite. See section 7.0.
Install the Injection/Check valve directly
into the piping system. To prevent
trapped gasses, install the fitting in an
upward direction.
Use PTFE thread
sealing tape on the pipe threads.
Push the opaque outlet (discharge)
tubing through the tube nut and onto the
compression barb of the Injection/Check
valve fitting. Hand tighten the tube nut
to secure the tubing.

FootValve
Strainer
Assembly

Ceramic
Weight

Suction Tubing

FOOTVALVE/STRAINER

! Outlet Tubing - Locate the outlet

fitting of the pump head. Remove the
tube nut. Push the opaque discharge
tubing through the tube nut and onto the
compression barb of the fitting. Hand
tighten the tube nut to secure the tubing.

Keep outlet tube as short as possible.

Discharge
Tubing

Tube retaining
nut

Injection
Check valve

INJECTION/CHECK VALVE

Pipe tee

Install
upward

C-1100V

CAUTION

ADJUST WHILE RUNNING

DISCHARGE LINES MAY BE

UNDER HIGH PRESSURE. USE

CARE TO PROTECT YOURSELF

WHEN DISCONNECTING.

MAX

MIN

1

2

3

4

5

6

7

8

9

LOOSEN THE LOCK SCREW

TURN KNOB TO DESIRED SETTING

RE-TIGHTEN THE LOCK SCREW

Advertising