Chassis queries and commands – Crystal nVision Lab Reference User Manual

Page 5

Advertising
background image

Chassis Queries and Commands

3

nVision Programming Instructions

Chassis Queries and Commands

3

chaSSIS QuerIeS and commandS

Queries

X

automatic Shutoff timer

AO?

. . . . . . . . . . Returns the auto off time in seconds. For example, 1200 is 20 minutes.

X

Firmware Version

VER?

. . . . . . . . . Returns the nVision firmware version in a R08XXXX.XX format.

X

message Store

MSG?

. . . . . . . . . Returns the data from the chassis message store.

X

model

MOD?

. . . . . . . . . Returns the model name of the chassis.

NV

is the nVision reference recorder, and

NL

is the nVision Lab Reference.

X

modules available

MODSA?

. . . . . . The available modules are returned as a sum of the following descriptors:

Lower Module =

1

Upper Module =

2

BARO Module =

4

Therefore, a number of 3 returned means that both the lower and upper modules are populated.

X

recording

REC:STA!

. . . (Run Tag) Starts a recording on the nVision, bypassing the screen lock if enabled (without unlocking the nVision)

examples . . .

REC:STA!

Starts a recording with a tag of “Run # N”, N being the number of recordings on the nVision.

REC:STA!Location1

Starts a recording with a tag of “Location1.” (Allows up to 22 characters.)

If you want to have spaces in the run tag, use:

REC:STA! HEX [Run Tag

*

]

Run Tag

*

is the run tag string converted to a hexadecimal represented string

example . . .

REC:STA! HEX 4c6f636174696f6e31

Starts a recording with a tag of “Location1.” (Allows up to 22 characters.)

If a blank run tag is desired use: REC:STA! HEX 20

REC:STO!

. . . Stops the current recording run, bypassing the screen lock if enabled (without unlocking the nVision)