1 UP

0.5

5 UP

2.5

DOWN N / A

DOWN

N / A

2 UP

1

6 UP

3

DOWN N / A

DOWN

N / A

3 UP

1.5

7 UP

4

DOWN N / A

DOWN

N / A

4 UP

2

8 UP

10

DOWN N / A

DOWN

N / A

SW3: Sensitivity (mV/V)

Bandwidth

There are two bandwidth settings available on the CSG110: 1 kHz (default), and 10 kHz.
To select the bandwidth, simply flip the DIP switch to the appropriate configuration.

Ex. If your application requires a higher bandwidth in order to account for the higher
frequency signals, such as those from dynamic applications, then you would want to
use the higher setting bandwidth.

UP

10

(3)

DOWN

1

SW4: Bandw idth

Current Setting

(4)

There are four current output settings available on the CSG110: 0-16 mA, 0-20 mA, 4-20
mA (default), and 5-25 mA. To select the current, simply flip the DIP switches to the
appropriate configuration.

SW5

SW6

SW7

Input Range (V) Output Range (mA)

DOWN

DOWN

DOWN

0-10

4-20

DOWN

DOWN

UP

0-10

5-25

UP

DOWN

DOWN

0-10

0-16

UP

DOWN

UP

0-10

0-20

DOWN

UP

DOWN

0-5

4-20

DOWN

UP

UP

0-5

5-25

UP

UP

DOWN

0-5

0-16

UP

UP

UP

0-5

0-20


Note: Only available with current output option.

(3) 25 kHz for QSH01498
(4) Only available with current output option