FUTEK IPM500 (D500) Digital Display User Manual

Page 43

Advertising
background image

43

Press Menu
Select Key

Press Digit Select
Key

Press Value Select
Key

_0000U

Line feed

0

No line feed after carriage return

1

Line feed after carriage return

_0000U

Alarm data with readings

0

No alarm data

1

Alarm data with reading

_0000U

Control of data output

0

Continuous data output

1

Data output on ASCII command only

.

SEr 2

.

Serial Setup 2

_0000U

Meter address with Custom
ASCII protocol

Select

1

thru

F

for addresses 1 thru 15.

Select

0.

thru

F.

(with decimal point) for

addresses 16 thru 31.

0

0000U

Half or full duplex

0

Full duplex

1

Half duplex

00000U

Special start & stop char.

0

Standard continuous mode

1

Special start & stop characters

00000U

RTS mode

0

Normal RTS

1

Single transmission

.

SEr 3

.

Serial Setup 3

00000U

Termination characters

0

Only at end of all items

1

At end of each item

.

SEr 3

.

Serial Setup 3
(continued)

00000U

Data sent in continuous
mode

0

Reading

1

Peak

2

Valley

3

Reading + peak

4

Reading + valley

5

Reading + peak + valley

__000U

Modbus ASCII gap timeout

0

1 sec

1

3 sec

2

5 sec

3

10 sec

__000U

Serial protocol

0

Custom ASCII

1

Modbus RTU

2

Modbus ASCII

SEr 4

.

Serial Setup 4.

__000U

Parity

0

None, 2 or more stop bits

1

Odd, 1 or more stop bits

2

Even, 1 or more stop bits

_

Addr

Modbus Address.
Appears only if a
Modbus protocol is
selected.

__000 __000 __000

Select digit to flash.

__247

Select

0

through

9

for flashing digit.

Address range is 1 to 247.