1 1 1 0 38:41 46:25

1 1 1 1 1:17:21 1:32:51

0 0 0 300 baud

0 0 1 600 baud

0 1 0 1200 baud

0 1 1 2400 baud

1 0 0 4800 baud

1 0 1 9600 baud

1 1 0 19200 baud
0 Send unfiltered value

1 Send filtered value

2F (L)

Filter

Bit 7 6 5 4 3 2 1 0

0 0 0 0 Auto Filter

0 0 0 1 Batch (16 samples) filter

Time constant 60 Hz 50 Hz

0 0 1 0 Moving average 0.07s 0.085s

0 0 1 1 Moving average 0.14 0.17

0 1 0 0 Moving average 0.28 0.34

0 1 0 1 Moving average 0.57 0.68

0 1 1 0 Moving average 1.13 1.36
0 1 1 1 Moving average 2.27 2.72

1 0 0 0 Moving average 4.53 5.44

1 0 0 1 Moving average 9.06 10.88
1 0 1 0 No filter (used with Hold)

0 Low adaptive threshold

1 High adaptive threshold

0 Display value of 16-reading batch
1 Display value of filtered signal

0 Take peak of unfiltered signal

1 Take peak of filtered signal

0 Alarm from unfiltered signal

1 Alarm from filtered signal

17 (L)

Serial Cnfg3

Bit 7 6 5 4 3 2 1 0

0 0 0 Net + Gross
0 0 1 Net only

0 1 0 Gross only

0 1 1 Peak only (Net or Gross)

1 0 0 Net + Gross + Peak
1 0 1 Valley only

1 1 0 Net + Gross + Peak + Valley

0 <CR> or <CR><LF> at end of all Items

1 <CR> or <CR><LF> at end of each Item

(if no Alarm character)

0 Non-latching RTS

1 Latching RTS

0 Normal continuous TX

1 Special Start & Stop characters

0 Full duplex

1 Half duplex

6D (L)

Count_

Bit 7 6 5 4 3 2 1 0 Auto-Zero Range

0 0 0 0 0 (no auto-zero)

0 0 0 1 ±1

0 0 1 0 ±2

0 0 1 1 ±3

0 1 0 0 ±4

0 1 0 1 ±5

0 1 1 0 ±6

0 1 1 1 ±7

1 0 0 0 ±8

1 0 0 1 ±9

Count By
0 0 0 1

0 0 1 2

0 1 0 5
0 1 1 10

1 0 0 20

1 0 1 50

1 1 0 100

35 (U)

Modbus Addr. 00 to FF Modbus address 0-255

(in Hex format)

2E (U)

Setup

Bit 7 6 5 4 3 2 1 0 EXT IN A EXT IN B

0 0 0 0 Meter Reset Meter Hold

0 0 0 1 Funct Reset Peak or Valley

0 0 1 0 Meter Hold Peak or Valley

0 0 1 1 Meter Hold Tare

0 1 0 0 Peak or Valley Tare

0 1 0 1 Meter Reset Tare

0 1 1 0 Funct Reset Tare

0 1 1 1 Tare Reset Tare

1 0 0 0 Display Blank Tare

1 0 0 1 Meter Reset Display Blank

Both Ext In A

& Ext In B =

Funct Reset

Funct Reset =

Alarms, Peak,
Valley

45