6 installation of the sk cu1-pbr customer unit, Installing the customer unit, Installation of the sk cu1-pbr customer unit – NORD Drivesystems BU0020 User Manual

Page 24

Advertising
background image

PROFIBUS DP

– Supplementary manual options for NORD - Frequency Inverters

24

BU 0020 GB-2612

2.2.6 Installation of the SK CU1-PBR customer unit

WARNING

Modules must not be inserted or removed unless the device is free of voltage. The slots
may only be used for the intended modules. Installation remote from the frequency inverter
is not possible. It must be connected directly to the frequency inverter.

Failure to comply with this may result in an electric shock, which my cause serious injury
and the destruction of the frequency inverter and the module.

Note

Following the insertion, replacement or removal of modules, and once the equipment
has been switched on again, this procedure is indicated with the message E017
Customer unit changed.

This message can be directly reset by the usual measures.

Installing the customer unit

1.

Switch off the mains voltage,
observe the waiting period.

2.

Remove the cover grille from the
connection area by loosening the 2
screws and levering out the device
cover (slot) or simply pull it out.

3.

Locking lever in the "„open
position.

4.

Using light pressure push the
customer unit into the upper guide
rail until it engages.

5.

Locking lever in the „closed
position.

6.

Remove the connector by pressing
the releases then make the
necessary connections. Then insert
the connectors until they engage.

7.

Replace all covers.

Kundenschnittstelle

Sondererweiterung

Technologiebox

Verrieglungsstift

CLOSED

OPEN

Verriegelung geschlossen

Verriegelung geöffnet

Customer

interface

Special

extension

Technology unit

Locking lever

Lock closed

Lock open