9 Telegram examples

BU 0020 GB-2612

91

9. Telegram examples

Various example telegrams are shown below to clarify the control and parameterisation of the
frequency inverter with the bus system.

Pos: 143 /Anleitungen/Bussysteme/8. Beispiel- Telegramme/Einschaltsperre -> Einschaltbereit [PBR] @ 1\mod_1336401062900_388.docx @ 25810 @ 255 @ 1

9.1 Switch-on block Standby

A frequency inverter is to be switched from the "Switch-on disabled" status (STW Bit 0

– 0), which is

active when the device is switched on, to the "Standby" status (STW Bit 0 = 1). Parameter set 1 is
valid. Only the PZD channel is evaluated.

Procedure:

Check last status word (ZSW 0B 70)

Generate control word (STW 04 7E)

Check response telegram (ZSW 0B 31)

Details:

Status word of frequency inverter  frequency inverter is in switch-on block status

Word

5

6

Byte

8

9

10

11

Designation

ZSW

IW1

Value

0B

70

00

00

Bit

Value

Value

HEX

Meaning

15

0

0

Parameter set Bit 1 off

14

0

Parameter set Bit 0 off

13

0

Reserved

12

0

Rotation left is off

11

1

B

Rotation right is on

10

0

Reference value undershot

9

1

Bus controller

8

1

Setpoint = actual value

7

0

7

No warning

6

1

Starting disabled

5

1

No emergency stop

4

1

Voltage not disabled

3

0

0

No fault

2

0

Operation disabled

1

0

Not ready for operation

0

0

Not on standby

Abbreviations used

PKW

Parameter

identifier

value

PZD

Process data

PKE

Parameter identifier

IND

Index

PWE

Parameter value

STW

Control word 1

ZSW

Status word1

SW1..3

Setpoint

IW1..3

Actual value