Installation

Initial Operational Settings

NOTE: Due to temperature and altitude changes, the
optimal settings for each truckmount must be
adjusted after installation. Failure to make these
adjustments may lead to poor unit performance and
premature component failure.

Vacuum Pump

The maximum vacuum pressure obtainable at full
throttle should be 13"Hg. If the unit is drawing a
stronger vacuum (at full sealed suction) than 13" Hg,
adjust the vacuum relief spring to 13" Hg.

Engine

Set RPM Values as shown below. Refer to Engine
Operation Manual for adjustment instructions.

*±50 rpm tolerance

Throttle

Load

RPM*

Idle

None

1200 rpm

Full

13" Hg. Vacuum

500 psi pressure

2750 rpm

Full

None

2850 rpm