Maintenance – Prochem Legend SE AD User Manual

Page 35

Advertising
background image

MAINTENANCE

LEGEND SE 980059 07/23/02

4-3

VACUUM PUMP

Refer to the Vacuum Pump Operation and Service
Manual for specific instructions.

Lubrication: We recommend that you use AEON
PD Synthetic Blower Lubricant in the gear end of the
vacuum pump for all operating temperatures. AEON
PD is formulated especially for positive displacement
blower service to provide maximum blower
protection at any temperature. One filling of AEON
PD will last a minimum of 2 times longer than a
premium mineral oil.

NOTE: AEON PD (Part # 05-008039) is the oil
which Prochem puts in the vacuum pump at the
factory. Topping off or adding petroleum oil to
synthetic oil is NOT recommended
.

If not using AEON PD synthetic blower lubricant,
use oils with rust and oxidation inhibitors, anti-foam
additives and the viscosity’s listed on the chart on
this page.

1. Check the oil level weekly to assure the proper

level. PROPER LEVEL cannot be
overemphasized. Too little oil will ruin bearings
and gears. Too much oil will cause overheating.
Use Figure 19 as a guide when adding oil.

2. To prevent rust from building up inside the

vacuum pump (if moisture exists) we have
provided a lubrication cup on the front of the
unit.

VACUUM PUMP LUBRICANT

BLOWER

DISCHARGE

TEMPERATURE

OIL

GRADE

U.S.A.

OIL VISCOSITY,

CENTISTOKES

@ 40°C

-40° TO 32°F

(-40° TO 0°C)

SAE 10W

45

32° TO 100°F

(0° TO 38°C)

SAE 20

100

100° TO 275°F

(38° TO 135°C)

SAE 40

200

OVER 275°F

(135°C)

SAE 50

250

* In applications with extreme variations in ambient

temperature a 20W-50W multiple viscosity oil is

recommended.

FOR GREASE LUBRICATED BEARINGS

Service every 500 hours or operation

Blower Discharge

Temperature

Type Grease

-40° to 275°F

(-40° TO 120°C)

Non-corrosive bearing

grease

First run the unit at least 1 minute to remove any
moisture from the vacuum pump. Next, fill the
lubrication cup with WD-40, or a similar lubricant, for
5 seconds while the unit is running and the vacuum
inlet is sealed. Do this at the end of each working
day
.

3. Drain, flush and replace oil every 1500 hours or

yearly, whichever comes first. Change oil
more frequently if inspection so indicates. With
AEON PD synthetic lubricant, perform the oil
change maintenance every 4500 hours or
every 2 years, whichever comes first.

4. The bearings on the pulley end of the vacuum

pump requires grease lubrication every 500
hours
. Pack the bearings until grease comes
out of the vent holes. Use extreme pressure
bearing grease of the specification NLGI Grade
2 EP.

OIL
LEVEL
SIGHT
GAUGE

VACUUM
PUMP
(side view)

OIL
LEVEL

(with vacuum pump
cold, engine off, and
unit on level ground)

Figure 19 VACUUM PUMP OIL LEVEL

Advertising