11 Specifications


Power supply

AC Adapter 12 VDC regulated,
100 or 300 mA

1)

DC(+) Tip

Operating limits at electronics

0…99 %RH (non condensing)

-10...55

°C (14...131°F)


Measured parameters

2)

relative humidity

indication range

0.0…100.0 %RH

temperature

indication range

-99.9…999.9

°C or °F

barometric

pressure

3)

indication

range

0.000…9999 hPa / PSI / In Hg


Calculated parameters

2) 4)

dew / frost point

5)

indication

range

-99.9…999.9

°C / °F

wet bulb temperature

6)

indication

range

0.0…100.0

°C / 32.0…212.0 °F

enthalpy

6)

indication range

-99.9…9999 J/g or BTU/lb

vapor concentration

indication range

0.000…9999 g/m3 or gr/cuft

specific

Humidity

6)

indication range

0.000…9999 g/kg or gr/lb

mixing

ratio

6)

indication range

0.000…9999 g/kg or gr/lb

vapor concentration at saturation indication range

0.000…9999 g/m3 or gr/cuft

part. pressure of water vapor

indication range

0.000…9999 hPa / PSI / In Hg

sat. pressure of water vapor

indication range

0.000…9999 hPa / PSI / In Hg


Number of probe inputs

HygroLab 1

2

HygroLab

2+3

4

Probe type

7)

All models

ROTRONIC HygroClip digital probe

All models

ROTRONIC analog probe

8)

HygroLab 2+3

Third-party analog probe

8)

A/D resolution (analog probes)

HygroLab 1+2

10-bit

A/D resolution (analog probes)

HygroLab 3

12-bit

Display

Alphanumerical LC display

Serial output (except HygroLab 1)

RS 232 / RS485

9)

Optional Ethernet interface

HygroLab 2+3

TCP/IP

Housing material

Aluminum

Housing dimensions

220 x 170 x 55 mm (8.66 x 6.69 x 2.16”)

Weight

1.0 kg (2.2 lb)

1) HygroLab with optional Ethernet module requires :

AC Adapter 12 VDC, 300 mA

2) Specify engineering units when ordering (can be changed by user with the optional HW4 software). See

separate probe specifications regarding the different range limits

3) Not available with HygroLab 1
4) Not available with HygroLab 1. The accuracy of the computed parameter is limited by the accuracy of the

measured parameters on which it is based

5) The standard factory setting is frost point for values below freezing. This setting can be changed to dew

point with the optional HW4 software

6) A fixed pressure value is used for the computations of this parameter. The fixed pressure value can be

changed by the user either from the keypad or with the optional HW4 software

.

The HygroLab 2 and 3 can

also be configured with the HW4 software to accept the input from a pressure probe (variable pressure
value)

Advertising