Setra System Model SRH User Manual

Page 4

Advertising
background image

4

Wiring 4 to 20 mA Output Units (2-wire / T0, T1 & T2)

Shield

TH2

TH1 / +V_TMP

RTN_TMP / +V_RH

RTN_RH / COM

+EXC

6 Earth Ground Connection
5
4
3 NC
2 RH (4 to 20 mA) Output
1 Vin

Thermistor/PRTD

Wiring 0-5 V/0-10 V Output Units (3-wire / T0, T1 & T2)

Shield

TH2

TH1 / +V_TMP

RTN_TMP/ +V_RH

RTN_RH / COM

+EXC

6 Earth Ground Connection
5
4
3 RH (0 to 5V/0 to 10V) Output
2 Ground
1 Vin

Note: Unit shipped in 0 to 5V Mode. Move jumper to right for 0 to 10V Operation

Selectable Outputs

Thermistor/PRTD

5V

10 V

H

Wiring 0-5 V/0-10 V Output Units (4-wire / T3 & T5)

Shield

TH2

TH1 / +V_TMP

RTN_TMP/ +V_RH

RTN_RH / COM

+EXC

6 Earth Ground Connection
5
4
3 RH (0 to 5V/0 to 10V) Output
2

Ground

1 Vin

Note: Unit shipped in 0 to 5V mode with Tspan set to 60°C. Move Tspan jumper to select
optional ranges.

Selectable Outputs

NC
Active Tmp (0-5V/0-10V )Output

5V

10 V

T

5V

10 V

H

40

50

60

Selectable Tspan

(°C)

Advertising