Setra System Model SRH User Manual

Page 5

Advertising
background image

5

Wiring 4 to 20 mA Output Units (3-wire / T3, T5)

Shield

TH2

TH1 / +V_TMP

RTN_TMP / +V_RH

RTN_RH / COM

+EXC

6 Earth Ground Connection
5
4
3 Active TMP (4-20 mA) Output
2 RH (4 to 20 mA) Output
1 Vin

N/C
N/C

Note: Unit shipped with Tspan set to 60°C. Move Tspan jumper to select optional ranges.

40

50

60

Selectable Tspan

(°C)

Advertising