Setra System 267MR User Manual

Page 7

Advertising
background image

3.3 Current Output Units - 1/2’’ Conduit Opening, PG9 or PG-13.5 Electrical
Termination


The Model 267 and 267MR is a two-wire loop-powered 4 to 20mA current
output unit (see Diagram 5). The current flows into +EXC. terminal and returns
back to the power supply through the -EXC. terminal (see Diagram 6). The
power supply must be a DC voltage source with a voltage range between 9
and 30 measured between terminal +EXC. and -EXC. The unit is calibrated with
a 24VDC loop supply voltage and a 250 ohm load.

4

Electrical
Connections

Range Select Switches
(267MR version only)

Diagram 5

+EXC -

Span

Zero

CONNECTION

9 pin D-sub Connector

Electrical Termination

+EXCITATION

4

+OUTPUT

1

COMMON

9

Diagram 4

Diagram 3

Excitation

Output

9 to 30 VAC / 11.5 to 42 VDC 0 to 5 VDC
12 to 30 VAC / 13 to 42 VDC 0 to 10 VDC

PIN 8, 9
COMMON

PIN 4

+EXC

PIN 1
+ OUTPUT

3.2 Voltage Output Units - 9 pin D-sub Connector Electrical Termination


The Model 267 and 267MR voltage output is a 3-wire circuit, with three pins avail-
able for wiring (see Diagram 3). The voltage output pin designations are shown in
Diagram 4:

267MR

9 to 30 VDC

+

_

Current

Monitor

Devce

8, 9

Diagram 6

*Pins 8 and 9 are internally commoned together, user can connect to either pin.