OUTPUT TEMPERATURE CHART

Out Put Temperature vs. GPM (Max. 14.5 GPM) with Various Ground Water Temperature

Correct Gas pipe size can be expect this chart

0.0

2.0

4.0

6.0

8.0

10.0

12.0

14.0

16.0

Out put Hot Water Temperature

O

u

t P

u

t H

o

t W

a

te

r G

P

M

40 F

50 F

60 F

70 F

40 F

10.1

9.3

8.7

8.1

7.6

7.1

6.7

6.4

6.1

5.5

5.1

4.9

4.7

4.5

4.3

4.2

50 F

12.1

11.0

10.1

9.3

8.7

8.1

7.6

7.1

6.7

6.1

5.5

5.3

5.1

4.9

4.7

4.5

60 F

14.5

13.5

12.1

11.0

10.1

9.3

8.7

8.1

7.6

6.7

6.1

5.8

5.5

5.3

5.1

4.9

70 F

14.5

14.5

14.5

13.5

12.1

11.0

10.1

9.3

8.7

7.6

6.7

6.4

6.1

5.8

5.5

5.3

100

105

110

115

120

125

130

135

140

150

160

165

170

175

180

185

LIMITED WARRANTY


1.

General terms of limited warranty:
This limited warranty gives you specific legal rights, and you may also have other rights which vary from State to State. The
manufacturer will honor the warranty to the original retail buyer at the original location only, and it is not transferable.

THIS

WARRANTY COVERS ONLY FAILED MECHANICAL AND ELECTRICAL PARTS DUE TO FACTORY
DEFECTS UNDER NORMAL USAGE FOR THE PRODUCT’S INTENDED PURPOSES AND WITHIN THE
APPLICABLE PERIOD SPECIFIED IN THE FOLLOWING TABLES. ONLY DIRECT DAMAGES SHALL BE
RECOVERABLE BY A CLAIMANT UNDER THIS LIMITED WARRANTY AND, IN NO EVENT, WHETHER AS
A RESULT OF BREACH OF CONTRACT, BREACH OF WARRANTY, TORT LIABILITY (INCLUDING
NEGLIGENCE), STRICT LIABILITY, INDEMNITY OR OTHERWISE WILL THE MANUFACTURER BE LIABLE
FOR ANY SPECIAL, INCIDENTAL, OR INDIRECT CONSEQUENTIAL DAMAGES INCLUDING PROPERTY
DAMAGE, PERSONAL DAMAGES, LOSS OF USE, OR INCONVENIENCE. SOME STATES DO NOT
ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE
ABOVE LIMITATION MAY NOT APPLY TO YOU.


2. Warranty

for

models: 910 (T-M50), 910 ASME (T-M50 ASME)

[Unit: Year]

Application

HX

(1)

Parts Labor

Single Family
Domestic Hot

Water

No Recirculation

12

5

1

(3)

On-Demand Recirculation

(2)

w/ Standard

Recirculation

Aquastat Control

5

Pump Control

Timer Only

3 3

No Pump Control (24 hr.)

Commercial

or

Multi-Family

Domestic Hot

Water

No Recirculation

5 5

1

(3)

On-Demand Recirculation

(2)

w/ Standard

Recirculation

Aquastat Control

Pump Control

Timer Only

3 3

No Pump Control (24 hr.)

Heating

(4)

All Types

5

5

1

(3)

*When the set temperature is 150ºF or higher, maximum flow rate is limited to 10.6 GPM.