Timeguard MLWTS User Manual

Page 6

Advertising
background image

CONNECTION DIAGRAM

Mains
Supply

Isolation Switch

SECTION FOUR

OPERATION AND TESTING

WALK TEST PROCEDURE
The sensor will rotate from left to right, and tilt forward or backward. Adjust the sensor
to point in the required direction. (note diagram B)

The unit can be set up in daylight or at night. The adjustment knobs are factory set.
Lux is set to the ‘Moon’ setting and Time is set to a minimum (fully anti-clockwise).
If not, set as shown in diagram G.

Turn the power to the unit on. The lamp will illuminate for approximately 30 seconds.
This indicates the unit is wired correctly.

After approximately 30 seconds the light will turn off. The unit is now in Test Mode.

The diagram below also shows the required connections for the addition of slave luminaires.
When adding slaves, be sure not to exceed the maximum switchable load (see Technical
Specifications). Metal encased luminaires which are not double insulated must be earthed.