Timeguard MLWTS User Manual
Page 8
Manual Override Mode is indicated by the permanent illumination of a single red LED
in the top of the sensor head.
To switch the unit back into Auto Mode, flick the internal wall switch/circuit breaker off/on
once within 1 second. The unit will return to Auto Mode. This is indicated by the return
of the left to right scrolling LED’s as described in Automatic Operation above.
HOLIDAY MODE – SINGLE LED FLASHING
The benefit of Holiday Mode is that the user can program the unit to automatically
illuminate for a certain time, (1 – 8 hours) each night. At dusk the unit will illuminate for
this set period after which it will extinguish. The unit will continue to operate normally
when it senses movement until dawn. At dusk the following night the process will
be repeated, the unit will remain on for this set period
(1 – 8 hours) then operate as a PIR unit until dawn.
HOLIDAY MODE
Switch the internal wall switch/circuit breaker 3 times (off/on off/on off/on) within 2 seconds.
A single flashing red LED at the top of the sensor head indicates Holiday Mode. The unit will
now illuminate for a user defined time between 1 and 8 hours. The time can be set by
rotating the centre adjustment knob as required. (See diagram G, the adjustment knob
is identified by the letter T inside a circle.)
Do not adjust this setting if you do not wish to use the Holiday Mode facility.
This time adjustment is factory set to 1 hour.
Please note: Fully anti-clockwise is 1 hour, fully clockwise is 8 hours.
After the defined period has elapsed, the unit will return to Automatic Mode and operate
as previously set up and the three scrolling LED’s will illuminate from left to right.
Holiday Mode will NOT reset to Automatic Mode at dawn, it will repeat each night
until reset by the user.
To cancel Holiday Mode, switch the internal wall switch/circuit breaker once (off/on)
within one second. The unit will turn to Automatic Mode indicated by the scrolling LEDs.
SECTION FIVE
TECHNICAL SPECIFICATIONS
Detection Range
Detection Angle
Power Supply
Maximum Switchable Load
(including fitted lamps)
Lamp Type
Time On Adjustment
Dusk Level Adjustment
Environmental Protection
Up to 12 metres
200º
230V AC ~ 50Hz
2850W Filament/Incandescent
or 375W Fluorescent/Low Energy
230V 75W PAR30 ES Reflector lamp x2
5 seconds – 18 minutes
Day & night or night only operation
IP55 (suitable for outdoor use)