Timeguard MLWTS User Manual

Page 8

Advertising
background image

Manual Override Mode is indicated by the permanent illumination of a single red LED

in the top of the sensor head.

To switch the unit back into Auto Mode, flick the internal wall switch/circuit breaker off/on

once within 1 second. The unit will return to Auto Mode. This is indicated by the return

of the left to right scrolling LED’s as described in Automatic Operation above.

HOLIDAY MODE – SINGLE LED FLASHING

The benefit of Holiday Mode is that the user can program the unit to automatically

illuminate for a certain time, (1 – 8 hours) each night. At dusk the unit will illuminate for

this set period after which it will extinguish. The unit will continue to operate normally

when it senses movement until dawn. At dusk the following night the process will

be repeated, the unit will remain on for this set period

(1 – 8 hours) then operate as a PIR unit until dawn.

HOLIDAY MODE

Switch the internal wall switch/circuit breaker 3 times (off/on off/on off/on) within 2 seconds.

A single flashing red LED at the top of the sensor head indicates Holiday Mode. The unit will

now illuminate for a user defined time between 1 and 8 hours. The time can be set by

rotating the centre adjustment knob as required. (See diagram G, the adjustment knob

is identified by the letter T inside a circle.)

Do not adjust this setting if you do not wish to use the Holiday Mode facility.

This time adjustment is factory set to 1 hour.

Please note: Fully anti-clockwise is 1 hour, fully clockwise is 8 hours.

After the defined period has elapsed, the unit will return to Automatic Mode and operate

as previously set up and the three scrolling LED’s will illuminate from left to right.

Holiday Mode will NOT reset to Automatic Mode at dawn, it will repeat each night

until reset by the user.

To cancel Holiday Mode, switch the internal wall switch/circuit breaker once (off/on)

within one second. The unit will turn to Automatic Mode indicated by the scrolling LEDs.

SECTION FIVE

TECHNICAL SPECIFICATIONS

Detection Range

Detection Angle

Power Supply

Maximum Switchable Load

(including fitted lamps)

Lamp Type

Time On Adjustment

Dusk Level Adjustment

Environmental Protection

Up to 12 metres

200º

230V AC ~ 50Hz

2850W Filament/Incandescent

or 375W Fluorescent/Low Energy

230V 75W PAR30 ES Reflector lamp x2

5 seconds – 18 minutes

Day & night or night only operation

IP55 (suitable for outdoor use)

Advertising