Setting up – Timeguard SLW360 User Manual

Page 7

Advertising
background image

6

Setting up

Walk Test Procedure

Set the two adjustment controls on the underside of the
unit (diagram C) to the following positions:

TIME - Fully anti-clockwise
DUSK - Fully clockwise

The unit will now operate during daytime as well as at
night, illuminating the lamp for approx. 5 seconds each
time. This allows testing to be carried out to establish the
best position for the sensor.
The lamp will immediately illuminate as the unit goes
through its "warm-up" period. After approximately 1 - 2
minutes the lamp will extinguish. Try to remain outside
the detection area during the warm-up period.
Walk around the sensor to establish the detection area.
The sensor will detect within an approximately six metre
diameter circle from the centre of the sensor location.
As you cross a detection "zone" the lamp will illuminate.
Now stand still until the lamp extinguishes (this should
take approx. 5 seconds).

See diagram “I” for ceiling mounting assembly method.
Fit the sensor assembly to the ceiling, if mounting
outdoors, it is essential that the sponge gasket is placed
between the ceiling mounting plate and the sensor
itself to ensure a good seal is maintained.
If mounting the unit indoors, the gasket is not required
and can be discarded.
Insert fixing screws through the sensor assembly into
the wall plugs and secure.
Do not overtighten, if using a power screwdriver
ensure it is set to a low torque setting so as not to
damage the unit.
Set the unit up as follows, before refitting the
decorative cover.