Timeguard 201.0.090 User Manual
Page 8
48
Switch-off delay time
Transfer areas
approx. 5min.
In the range between 2 - 15min the switch-off delay varies according to
its self-learning behavior. The set values <2min or >15min remain fixed.
«Pulse»: staircase lighting timer control (0.5s “on” / 10s “off”)
DIP switch
Fully / Semi-automatic mode
«auto»: Fully automatic mode. The lighting is switched on automatically.
«man»: Semi-automatic mode. The lighting must be switched on manually.
Push-button function: room / corridor
«room»: Manual switching on/off possible.
«corridor»: Detector is used as staircase lighting timer.
No manual switching-off possible.
Push-button/Switch control
Optional push-button or switch operation.
Multiple push-buttons on one control input possible.
Use illuminated push-buttons with PEN conductor connection only.
●
●
●
●
●
●
●
●
●
●