Timeguard 202.0.000 User Manual

Page 12

Advertising
background image

2

.3 Behaviour on switching on

After you have defined the settings, connect the upper part to the power

section. Ensure that the labelling is aligned on both parts.
Each time the sensor head is attached to the power section or after the

power supply is connected, a startup phase (90 sec.) followed by a ser-

vice phase (10 min.) is initiated on the sensor. The sensor then switches

to normal operation automatically.

Avoid using force when assembling the unit. Ensure that the two

parts are aligned correctly.

Do not press on the lens. Hold the upper part at the white edge only.
The two switching contacts are closed for approx. 90 sec. after the unit

has been assembled (startup phase).
The lighting system lights up continuously and the ventilation system is

in operation.
In the subsequent service phase, the ECO-IR responds immediately to

changes in brightness in order to test the set brightness switching value

(Lux) quickly.
If the room is darkened (e.g. by closing the blinds), the lighting system

is switched on when the switching value is reached. The lights can be

switched off by „blinding“ the sensor with a torch.