6.3 Composition of an RTU request message (transmitted from a high-level

computer to this product)

n For codes a) through i), see "6.5. Description of RTU codes."

6.3.1 Composition of a read request message

a) Slave address

1BH

b) Function code

03H

High level

00H

c) Register address

Low level

00H

First register address

High level

00H

d) Number of registers

Low level

02H

2 to 100 (even number only)

High level

C6H

e) CRC-16

Low level

31H


6.3.2 Composition of a write request message

Multiple

a) Slave address

03H

b) Function code

10H

High level

00H

c) Register address

Low level

C0H

First register address

High level

00H

d) Number of registers

Low level

02H

Fixed at 2

f)

Number of data items

04H

Number of registers

×

2

High level

00H

Data for the first register
(a low-level word)

Low level

6FH

High level

00H

g)

Data for the first register + 1
(a high-level word)

Low level

00H

When writing ①, ②, ③, and

④ H in the data, write them in
the order described on the
left-hand side. (① represents 1
byte.)

High level

C4H

e) CRC-16

Low level

5AH

Single

a) Slave address

03H

b) Function code

06H

High level

00H

c) Register address

Low level

C0H

First register address

High level

00H

g)

Data for the first register
(a low-level word)

Low level

6FH

High level

C4H

e) CRC-16

Low level

5AH

When writing ① and ② H in
the data, write them in the order
described on the left-hand side.
(① represents 1 byte.)

21