Environmental Considerations

• The UNIPLAY are to be used indoors as built

in displays. Make sure that the display are

installed correctly and that the operating limits

are followed.

• Do not operate the unit in areas subject to

explosion hazards due to flammable gases,

vapours or dusts.

• The unit should not be installed where large

temperature variations and/or high humidity

is present. This will cause condensation in the

device.

• Do not install UNIPLAY in environments where

have inflammable gases.

MOUNTING

Care should be taken when locating equipment

behind the unit to ensure that a.c. power

wiring, PLC output modules, contactors, starters

and relays, and any other source of electrical

interference are located away from the back of

the unit. Particular note should be taken to the

position of variable speed drives and switching

power supplies. Their input and load cables

should be screened to a central star earth point.

Making a NEMA-4 Mounting Panel Details

The unit can be mounted into panels with a depth

of 105mm. It is recommended that the unit be

mounted on the front panel of a steel enclosure,

through an appropriate opening.
Allow a clearance of 25mm around the sides of

the unit for mounting hardware. Allow clearance

for cable connections to the back of the unit.

Unit depth may vary according to cable type

used. Typically, plan a depth to accommodate at

least 105mm behind the panel.

This device should be mounted in the vertical

position on a flat surface of the enclosure.

NEMA-4 Mounting

Put the unit through the panel cut out (See

drawings at the back of this guide). Slide the

clamps (packed with product) into the 4 holes

provided around the case. Tighten the clamping

screws in an even pattern until the unit is secured

in the panel. Screw torque: 0.29 - 0.39 Nm. This

ensures a waterproof seal and prevents the panel

from being deformed.

VESA Mounting

There are 4 holes on back panel for attaching a

VESA mount. 4 x M4 screws of length shorter then

8.0mm required. Screw torque: 0.29 Nm.

0

DO NOT OVER TIGHTEN MOUNTING CLAMPS!

To seal to NEMA-4 specifications, all

supplied mounting clamps must be

used and panel cannot flex more than

0.253mm.

POWER CONNECTIONS

Make sure that all local and national electrical

standards are met when installing the unit.
Contact your local authorities to determine which

codes apply.

Power Requirements

The UNIPLAY is powered by d.c. power only. The

specified voltage range is 24±20% Volts d.c. This

insures compatibility with most controller d.c.

systems.