Grounding requirements – Trio Motion Technology Uniplay HMI User Manual

Page 9

Advertising
background image

9

Quick Start Guides

The power conditioning circuitry inside the unit

is accomplished by a switching power supply. The

peak starting current can be as high as 2A.

Fusing Requirements

If the display does not come on within 5 seconds

of power up, switch off the power. An internal

fuse will prevent damage if the polarity of the

d.c. power is incorrect. Check wiring to insure

proper connections and try to power up again.

High Voltage

An Internal fuse will prevent damage for over

voltage condition however it is not guaranteed.
D.c. voltage sources should provide proper

isolation from main a.c. power and similar

hazards.

Emergency Stop

A Hard-wired EMERGENCY STOP should be fitted

in any system using a UNIPLAY to comply with ICS

Safety Recommendations.

Supply Voltage Condition

Do not power the UNIPLAY and inductive d.c.

loads, or input circuitry to the controller, with

the same power supply.

The 24 Vd.c. output from some

controllers may not have enough current

to power the UNIPLAY.

Wire Routing

Wire lengths should be minimized (Maximum

length: 500m shielded, 300m unshielded).
Wires should be run in pairs with a neutral or

common paired with a signal line.

If wiring is to be exposed to lightning or surges,

use appropriate surge suppression devices.
Keep a.c., high energy, and rapidly switching d.c.

wiring separate from the 3 signal wires.
Fit ungrounded d.c. supplies with a resistor

and capacitor in parallel to earth ground. This

provides a path for static and high frequency

dissipation. Typical values to use are 1MΩ and

4700pF.

To prevent the UNIPLAY from becoming

damaged or having noise output issues,

after turning the device off, please wait

10 seconds before turning the device on

again.

Connection

To make a connection, strip

about 10mm of insulation

off the end of the wire,

turn the connector screw

counterclockwise until the

gap is wide open, insert

the wire all the way in, and

turn the screw clockwise

until tight. Connect positive d.c. line to the +24V

terminal and the d.c. ground to the 0V terminal.

GROUNDING REQUIREMENTS

0

A CHASSIS GROUND MUST BE USED.

The d.c. ground is not directly coupled to Earth

ground internally. It is not advisable to ground

the d.c. negative return to chassis ground as poor

site earthing can introduce noise into a system,

but if necessary an earth connection should be

made, from the power supply return point to

GND