Please commn calibrt using above paper, Please calibrate using above paper, Blue platen switch is dirty – Canon imagePROGRAF iPF6400S User Manual

Page 985: Cannot adjust paper feed

Advertising
background image

Please commn calibrt using above paper.

Please commn calibrt using above paper.

Cause

Corrective Action

It is now recommended that you execute Common calibration.
Note that this is displayed when Set Exec. Guide in the Control Panel menu is set to On and any of the following
is true.

If the printer is loaded with a type of paper on which color calibration cannot be executed and the predefined
conditions since executing the Common calibration the last time have been reached.

Although a media type that color calibration can be executed on is loaded in the printer, there is no record or
performing color calibration on that media, and the designated criteria from executing Common calibration
the last time have been reached.

Execute Common calibra-
tion.
(See "Color Calibration Us-
ing the Printer Sen-
sor.")

P.793

Set Set Exec. Guide to Off
on the Control Panel menu.
(See "Menu Struc-
ture.")

P.628

Please calibrate using above paper.

Please calibrate using above paper.

Cause

Corrective Action

It is now recommended that you execute Unique calibration.
Note that this is displayed when Set Exec. Guide in the Control Panel menu is set to On and any of the
following is true.

If the printer is loaded with a type of paper on which color calibration can be executed, but there is no
record of having executed color calibration on that paper or a record of having executed Common calibra-
tion other any other type of paper.

If the printer is loaded with a type of paper on which color calibration can be executed, there is a record of
having executed color calibration on that paper, and the predefined conditions since executing the color
calibration the last time have been reached.

The Spectrophotometer Unit (optional) is installed. Although a media type that color calibration can be
executed on using the Spectrophotometer Unit is loaded in the printer and the result of a color check on
that media exceeded the threshold value, the color calibration has not been performed.
(See "Color Checks Using the Spectrophotometer Unit (option).")

P.802

Execute Unique calibration.
(See "Color Calibration Using
the Printer Sensor.")

P.793

(See "Color Calibration Using
the Spectrophotometer Unit
(option).")

P.799

Set Set Exec. Guide to Off on
the Control Panel menu.
(See "Menu Struc-
ture.")

P.628

Before borderless printing, move the blue platen switch.

Before borderless printing, move the blue platen switch.

Cause

Corrective Action

The blue Switch on the platen was set to the side opposite ● when
a borderless print job was received.

Before borderless printing, set the blue Switch on the platen to the ● side.
(See "Setting the Blue Switch on the Platen.")

P.955

Blue platen switch is dirty.

Blue platen switch is dirty.

Cause

Corrective Action

The blue Switch on the platen is dirty. Open the Top Cover and clean the blue Switch on the platen.

(See "Cleaning Inside the Top Cover.")

P.907

Move the blue platen switch No.xx to the right. (xx represents a number)

Move the blue platen switch No.xx to the right. (xx represents a number)

Cause

Corrective Action

The printer has detected that the blue Switch on the platen needed in main-
tenance during printing is set away from the ● mark.

Set blue platen Switch of the indicated number toward the ● side.
(See "Setting the Blue Switch on the Platen.")

P.955

Cannot adjust paper feed.

Cannot adjust paper feed.

Cause

Corrective Action

The Printhead nozzles are clogged.

Execute Adj. Quality again, as follows.

1.

Press the OK button to clear the error.

2.

Print a test pattern to check the nozzles.
(See "Checking for Nozzle Clogging.")

P.890

iPF6400S

Please commn calibrt using above paper.

User's Guide

Error Message

Messages regarding printing or adjustment

985

Advertising