Time code signal output, Time code signal output 91, Cop y – Canon XF305 User Manual

Page 91

Advertising
background image

91

Recording

3

b Synchronizing with an External
Device

• The camcorder will synchronize to an external 30 fps time code signal,

or an external 59.94i signal input through the GENLOCK terminal.

• If the external Genlock signal is incorrect or there is no input signal, the

external time code that is recorded may be incorrect.

• While a time code signal is being received, the external time code’s

drop-frame bit will be used (if the external time code is non-drop frame,
[NDF] will appear on the side panel).

• When an external time code signal is received, the camcorder’s own

time code will be synchronized to it and the synchronization will be
maintained even if you disconnect the cable from the TIME CODE
terminal. However, performing any of the following actions while the
cable is not connected will cause the synchronization to be disrupted;
the correct time code will be restored once you reconnect the cable.
- Turning the camcorder off/on
- Changing the operating mode to

mode

- Changing the video configuration
- Changing the frame rate

• If the external time code signal is incorrect or there is no input signal,

the internal time code set in the [L TC/UB Setup]

[Time Code]

submenu will be recorded instead.

• When the camcorder locks on an external time code signal,

[EXT-LOCK] appears on the side panel.

Time Code Signal Output

The time code will be output from the TIME CODE terminal as an SMPTE-
standard LTC timing signal. The user bit will also be output. Before
connecting the device, set the TIME CODE terminal to output. If you set
the [N Video Setup]

[SDI Output] setting to [HD] or [SD], the

embedded time code will be output from the HD/SD SDI terminal.

NOTES

• The user bit of the time code signal is output while the camcorder is

recording in

mode or during playback of a clip in

mode.

When the [J Other Functions]

[Frame Rate] setting is set to [24P]

and the [L TC/UB Setup]

[User Bit]

[Output Mode] setting is

set to [Pulldown], the user bit will be 2:3 pulldown data. In other words,
when a recording in 24P mode is output from the HD/SD SDI terminal,
the signal is converted to 60i using the 2:3 pulldown method. An
external device can receive the data used in this conversion (2:3
pulldown data) to convert the signal to 1080/24P specifications.

Operating modes:

COP

Y

Advertising