Technical details, Installation, Unpacking – Electrolux EFP6440X User Manual

Page 42: Fitting, Electrical connection (not for uk), Fig. 6 - fitting, Electrical connection for uk only

Advertising
background image

42

Technical Details

EFP 6440

EFP 6411

Dimensions (in cm):

Height

17,3

17,3

Width

59,8

59,8

Depth

29,5 -45

29,5 -45

Maximum absorbed power: 330 W

200 W

Motor absorption:

2 x 125 W

1 x 120 W

Lighting:

2 x 40 W

2 x 40 W

Length of the cable:

150 cm

150 cm

Electrical connection:

220-230 V

220-240 V

Subject to change without notice.

Installation

Unpacking

Check that the cooker hood has no damages.

Transportation damages should immediately be

reported to the company responsible for the

transportation.

Damages, faults and eventually missing details

should immediately be reported to the retailer.

Take care of the packing materials so that small

children cannot play with them.

Fitting

The hood is to be mounted on the wall.

When installed, the hood must be not less than 50

cm. above electric burners or 65 cm. above gas or

mixed-fuel burners.

The hood can be installed above these heights but

for optimum performance it should be installed at

the distance quoted for the appropriate heat source.

Electrical connection (not for

UK)

Safety warnings for the electrician

Before connecting the appliance to the power

supply, check that the voltage indicated on the

rating plate corresponds to the mains power supply

available. Appliances fitted with a plug can be

connected to any standard power socket within

easy access.

Should it be necessary to provide a fixed

connection, the hood must only be installed by an

electrician authorised by the local electricity board.

When installing, an omnipolar disconnector with a

distance of at least 3 mm between contacts must

be provided.

Fixed connection of the appliance must only be

carried out by an authorised electrician.

Fig. 6 - Fitting

Min

65 cm

Min

50 cm

Electrical connection for UK

only

Safety warnings for the electrician

Connect the hood to the mains supply via a double

pole switch which has 3 mm minimum separation

between the contacts.

The switch must be accessible at all times.

The following is valid in the United Kingdom only:

- the wire which is coloured green and yellow

must be connected to the terminal which is

marked with the letter E or by the earth symbol

( ), or coloured green or green and yellow;

- the wire which is coloured blue must be

connected to the terminal which is marked with

the letter N or coloured black, -

- the wire which is coloured brown must be

connected to the terminal which is marked with

the letter L or coloured red.

Advertising