Single Station Installation

In a Single Stage installation, there are no additional KVM switches cascaded
down from the KH1508 / KH1516. To set up a single stage installation, refer
to the installation diagrams starting on page 13 (the numbers in the diagram
correspond with the numbers of the instruction steps), and do the following:

1. Plug your Local Console’s keyboard, monitor, and mouse into the unit’s

Console Ports. Each port is color coded and marked with an appropriate
icon to identify itself.

2. Use Cat. 5 cable to connect any available KVM port to a KVM Adapter

Cable that is appropriate for the computer you are installing (see KVM
Adapter Cables (CPU Modules)
, page 4 for details).

Note: The KH1508 / KH1516 does not support distances between itself

and the KVM Adapter Cable that exceed 40 m.

3. Connect the KVM Adapter Cable to the computer.

Plug the connectors on the KVM Adapter Cable into the appropriate ports
of the computer you are installing. (See KVM Adapter Cable Installation
Diagrams
, page 14 for connection
examples.)

4. Plug the female end of the power cord into the KH1508 / KH1516's Power

Socket; plug the male end into an AC power source.

5. Turn on the power to the KH1508 / KH1516.

After the KH1508 / KH1516 is powered up, you can turn on the computers.