Connecting the Appliance

Have a technician install and connect the appliance

according to the enclosed Installation Instructions.
Do not remove the transportation protection devices

from the shelves and storage compartments until

the appliance has been installed.
Always connect the water before the power.
Apart from statutory national regulations, you should

comply with all applicable local electricity and water

companies codes and requirements.
After installing the appliance, wait at least 1 hour before

switching the appliance On. During transportation

the oil in the compressor may have flowed into

the refrigeration system.
Before switching the appliance On for the first time,

clean the interior of the appliance (see chapter

“Cleaning the Appliance”).

Water Connection

,

CAUTION:
Connect the appliance to a drinking water line

only:

Minimum pressure: 0.2 Mpa (2 bar)

Maximum pressure: 0.8 Mpa (8 bar)

Pressure over 0.8 MPa (8 bar): install

a pressure limiter between drinking water

connection and hose set:

The water may be connected only by a competent fitter

according to the local regulations of the appropriate

Water Supply company.
A cold water connection is necessary for operating

the automatic Ice Maker. The water pressure must be

between 29 and 116 p.s.i. (2.0 and 8.0 bar). The

installation must correspond to the local plumbing

regulations.
A separate Shut-Off-Valve should be installed in

the cold-water inflow.
The Shut-Off-Valve should not be located behind

the appliance. It is recommended that you mount

the Shut-Off-Valve directly next to the appliance or at

another place that is easily accessible.
When installing the water connection, pay attention to

the permissible installation area for the water line.
For connection to the drinking water line use only water

pipes that are suitable for drinking water. Observe

national regulations and the connection conditions of

the local Water Supply companies.

Electrical Connection

,

WARNING:
Avoid the risk of an electric shock!

,

WARNING:
Insert into a grounded 3-phase receptacle. Never

remove grounding phase. Do not use any

adapters. Do not use any extension cords.

,

WARNING:
Non-compliance with these instructions may

result in death, fire or an electric shock.

Improper connection of the protective conductor

may result in an electric shock. If you are in

doubt whether the appliance has been grounded

properly, have the appliance tested by

a qualified electrician or service technician.

Do not use extensions or distributors.
The receptacle must be installed according to the

Installation Manual.
The appliance complies with protection class I.

Connect the appliance to 115 V/60 Hz AC through

a correctly installed 3-pole grounded receptacle.

The receptacle must be protected with a 10 to 16 A

fuse.
The appliance comes with a UL registered 3-wire

Power Cord.
Please see the following table:

Check on the Rating Plate whether the indicated

voltage and current type correspond with the values of

your power supply. The location of the Rating Plate

can be found in the chapter “Customer Service”.

,

WARNING:
Never connect the appliance to electronic

energy saving devices.
Our appliances can be used with power line and

sine-controlled inverters. Power line-controlled

inverters are used for photovoltaic systems

which are connected directly to the national grid.

Sine-controlled inverters must be used for

isolated applications (e.g. on ships or

in mountain lodges) which are not connected

directly to the national grid.

Appliance

Maximum Simultaneous Load

Fridge-

freezer

6.0 amps