Screw the protective film on the pump on again, Insert the service cover snap it in, and close it, Notice – Bosch WAP24200UC User Manual

Page 28

Advertising
background image

28

5.

Use the pull-out drain hose located in the pump

access opening to drain the remaining water into a

suitable container (up to 5.3 U.S. gallons/20 liters of

water may be drained). Pull the sealing cap from the

hose and lay the hose over the side of the container

and allow the water to finish draining from the drum.

When finished, replace the sealing cap into the end of

the hose and restore the hose to its storage location.

6.

Turn the pump cover counterclockwise to remove it. A

small amount of residual water may flow out when the

cover is removed.

Clean the interior of the pump housing, removing any

debris or foreign objects. Check to be sure the

impeller wheel at the back of the pump housing can

now turn freely.

Remove any lint, debris or detergent residue from the

threads of the pump cover and the pump cover

housing.

Replace the pump cover and tighten the screws.

Handle must be vertical.

7.

Screw the protective film on the pump on again.

8.

Insert the service cover snap it in, and close it.

NOTICE: In order to prevent detergent from flowing

unused into the drain during the next wash cycles: pour

0.26 U.S. gallons/1 liter water into the chamber II.
Turn the cycle selector to the Spin/Drain cycle, select No

spin and press the Start/Pause button.