Rough-in-dimensions, Heater performance data – A.O. Smith 200M User Manual

Page 2

Advertising
background image

2

ROUGH-IN-DIMENSIONS

HEATER PERFORMANCE DATA

NOTE: To compensate for the effects of high altitude areas above 2000 feet, input rating, and therefore recovery ratings, should be
reduced approximately 4% for each 1000 feet above sea level.

Recovery rating of models shown in chart above are obtained by actual efficiency test data by recognized Certification Agency.

NOTE:

Recovery rate shown on each models rating plate is based on the requirements of ANSI Standard Z21.10.3, which stipulates
the data to be based on energy efficiency of 75%.

TABLE 3 - CAPACITY AND GAS AND ELECTRIC CHARACTERISTICS

Manifold Pressure

Maximum Supply Pressure Electrical Characteristics

Model

Type of Gas

Inches W.C.

kPa

Inches W.C.

kPa

Volts/Hz

Amperes

HW-120M thru 225M

NATURAL

3.5

0.87

10.5

2.61

120/60

<5

HW-120M thru 200M

PROPANE

10

2.49

13.0

3.23

120/60

<5

Minimum Supply Pressure, Natural Gas: 4.5 inches W.C. (1.12 kPa)
Minimum Supply Pressure, Propane Gas: 11.0 inches W.C. (1.74 kPa)
Minimum Pressure must be maintained under both load and no load (static and dynamic) conditions.

Models

HW-120M HW-160M HW-200M HW-200M

Dimensions

Inches

mm

Inches

mm

Inches

mm

Inches

mm

A

49 3/8

1254

50 1/8

1273

53 1/4

1353

60

1524

B

30 3/8

772

30 3/8

772

33 1/8

841

33 1/8

841

C

23 5/8

600

23 5/8

600

27 1/8

689

27 1/8

689

D

20 3/4

527

20 3/4

527

20 3/4

527

20 3/4

527

E

5 1/2

140

5 1/2

140

5 1/2

140

5 1/2

140

F

10

254

10

254

10

254

10

254

G

11 13/16

300

11 13/16

300

11 13/16

300

11 13/16

300

H

6

152

7

178

7

178

7

178

J

26 11/16

678

26 11/16

678

26 11/16

678

26 11/16

678

K

20 3/4

527

20 3/4

527

20 3/4

527

20 3/4

527

L

1 1/4 NPT 1 1/4 NPT 1 1/4 NPT 1 1/4 NPT

M

1 NPT

1 NPT

1 NPT

1 NPT

N

1/2 NPT

1/2 NPT

1/2 NPT

1/2 NPT

W

1 3/4

44

1 3/4

44

1 3/4

44

1 3/4

44

Approx.

Shipping

120 lbs.

54 Kg.

155 lbs.

70 Kg.

165 Lbs.

75 Kg.

175 lbs.

79 Kg.

Weight

TABLE 1 - ROUGH-IN DIMENSIONS

TABLE 2 - RECOVERY CAPACITIES

U.S. Gallons/Hrs. and Litres/Hr. at TEMPERATURE RISE INDICATED

Input

20F°

30F°

36F°

40F°

50F°

54F°

60F°

70F°

72F°

80F°

90F°

100F°

108F°

110F°

120F°

126F° 130F° 140F°

Model

Btuh

KW

11.1C° 16.6C° 20C° 22.2C° 27.7C° 30C° 33.3C° 38.8C° 40C°

44.4°

50C° 55.5C°

60C° 61.1C° 66.6C° 70C° 72.2C° 77.7C°

120,000

GPH

605

403

336

303

242

224

202

173

168

151

134

121

112

110

101

96

93

86

35

LPH

2290

1527

1272

1145

916

848

763

654

636

573

509

458

242

416

382

364

352

327

160,000

GPH

777

518

432

388

311

288

259

222

216

194

173

155

144

141

129

123

120

111

47

LPH

2941

1961

1634

1471

1176

1089

980

840

817

735

654

588

545

535

490

467

452

420

199,000

GPH

987

658

548

494

395

366

329

282

274

247

219

197

183

179

165

157

152

141

58

LPH

3737

2491

2076

1869

1495

1384

1246

1068

1038

934

830

747

692

679

623

593

575

534

225,000

GPH

1096

731

609

548

438

406

365

313

304

274

244

219

203

199

183

174

169

157

66

LPH

4149

2766

2305

2074

1659

1537

1383

1185

1152

1037

922

830

768

754

691

659

638

593

HW-120M

HW-160M

HW-200M

HW-2250M

Advertising
This manual is related to the following products: