CHART 2

S8600 (NATURAL GAS AND LP GAS)

INTERMITTENT PILOT SYSTEM TROUBLESHOOTING

PILOT BURNER LIGHTS BUT MAIN BURNER DOES NOT LIGHT

Does the pilot flame cover 3/8” to 1/2”

of igniter/sensor rod?

Does spark stay on for more than 30 seconds

after the pilot is “proven” (lit)?

Is the pilot burner ignition cable in good

condition (not brittle, burnt, or cracked)?

Are the ceramic insulators surrounding the

igniter/sensor rod in good condition

(not broken or cracked)?

Are the igniter/sensor rod in good

condition (not worn, corroded, sooted

or damaged)?

Replace ignition module.

Correct the situation by consulting the

installation or user’s manual on how to

adjust pilot flame.

Is voltage (24 Vac) across terminals

MV & MV/PV?

Are the wires securely attached to the main

valve operator on the gas control and to

terminals MV & MV/PV on ignition module?

Replace

ignition

module.

Replace main gas valve.

Replace pilot burner.

Replace pilot burner.

Clean rod or replace

pilot burner if necessary.

Attach

wires

firmly.

YES

YES

YES

YES

YES

NO

NO

NO

NO

NO

NO

NO