Specifications, Heating specifications, Dimensions – Avalon Stoves Indoor Fireplace User Manual

Page 6: Electrical specifications, Fuel, Epa compliance

Advertising
background image

6

Specifications

Travis Industries

4 0 5 0 5 2 5

1 0 0 - 0 1 1 4 4

Heating Specifications:

Approximate Maximum Heating Capacity (in square feet)* ........................................800 to 2,250
Burn Rate (Pounds per Hour)**............................................................................1.7 to 5.5
Maximum Burn Time on Low Burn** ......................................................................28 to 52 Hours
Hopper Capacity (based upon hopper extension position).........................................48 to 89 Pounds

*

Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature. It is also
affected by the fuel size, quality, and moisture level.

**

Small pellets will increase or decrease the stated burn rates and burn times. Differences of plus or minus 20% depending
on fuel quality may occur.

Dimensions:

12"

13-1/4” (allow 14” depth in the Fireplace)

32”

Center of 4” diameter Flue is 16-7/8” above the
baseplate and 7-1/2” left of center

25-3/4” to 20”

See “Hopper Extension Set-up”

for details.

25-1/2” (allow 36” width for

control board installation)

26-1/2”

45”

28”

Door Opening

Fireplace Opening

Electrical Specifications:

Electrical Rating.........................................................................................115 Volts, 3.6 Amps, 60 Hz
Watts During Start-Up Sequence ...................................................................400 (approximately)
Watts During Operation ...............................................................................180 (approximately)

Fuel:

• This heater is designed and approved for pelletized wood fuel or a mixture up to 50% corn, 50% pellets.

See page 23 for details on using a corn pellet mix.

EPA Compliance:

This heater is EPA exempt from Phase II requirements, but has been tested for emissions using EPA
test methods by OMNI Test Labs.

Advertising