Cold start, Pressing the config button twice – Agilent Technologies J3972A User Manual

Page 116

Advertising
background image

Probe Operation
Restarting the Probe

96

3. Press

7

to execute a warm start and exit the probe’s Main Menu. The warm

start occurs immediately. The Activity and Fault LEDs are turned on during
a warm start. When the warm start completes, the Activity LED flashes to
indicate traffic (if present), the Fault LED turns off, and the ~Line On (or
Power) LED is on.

Cold Start

A cold start resets all of the probe’s measurement data as well as all alarm, event,
filter, and user-defined statistics configuration to their default values. Basic
communications configuration parameters (IP address, default gateway IP
address, and subnet mask) are not reset.

You can cold start the probe by doing one of the following:

z

Pressing the CONFIG Button twice within one second.

z

Selecting the menu item Cold start and Exit from the probe’s Main Menu
when you have a local terminal connected to the probe, as described on
page 97.

z

Using NetMetrix to execute a probe cold start. Refer to your NetMetrix
documentation for details.

Table 5-1 on page 94 shows which data and parameters are reset during a cold
start or warm start of the probe.

Pressing the CONFIG Button Twice

Pressing the CONFIG button twice within one second causes the probe to cold
start.