Local Terminal Configuration

Using a Local Terminal

33

OC-3 ATM Interface Configuration

You must configure two of the three ports on the probe’s OC-3 ATM interface.
The third port cannot be configured. Use the following procedure to configure
items in the Modify/View Interface Values menu for the first port on the OC-3
ATM interface:

1. Press

3

to access the Modify/View interface values menu item. The

Modify/View Interface Values menu for port 1 is displayed, as shown in
Figure 2-7.

Figure 2-7: Modify/View Interface Values Menu (OC-3 ATM, Port 1)

2. Select each field requiring configuration (one at a time) by pressing its

corresponding number and then entering the values that are appropriate for
your network.

Port

Press

1

and then enter the OC-3 ATM interface’s port number

to display the OC-3 ATM port’s configuration parameters
along with their current settings. Refer to “Display Interface
Summary” on page 36
for information on port types and port
numbers for the installed interfaces. You can then view or
configure the OC-3 ATM port’s configuration parameters.

Port Type

Press

2

and select the port type as Monitor-only.

Modify/View Interface Values Menu - Firmware Rev

Interface Type

STS3C/STM1

1. Port

3.1/STS3C-STM1

2. Port Type

Monitor-only

3. Cell Sychronization

HEC

4. Cell Scrambling

On

S. Save changes and exit

0. Cancel changes and exit