Front panel status indicator led – ADC and 3 Doubler User Manual

Page 11

Advertising
background image

LTPH-UM-1234-01

Product

Description

HDU-409 Lists 1, 2, and 3

April 30, 2003

5

Table 2.

Front Panel Status Indicator LED

LED

Description

Flashing Red about
once per second

Indicates an HDSL Cyclic Redundancy Check (CRC) error has
occurred between the HDU-409 and the upstream module.

Flashing Red rapidly

Indicates an HDSL CRC error has occurred between the
HDU-409 and the downstream module.

Flashing Yellow about
once per second

Indicates a Network Doubler Unit (NDU) loopback is in effect in
the HDU-409 towards the network. This tests the integrity of the
upstream span.

Flashing Yellow
rapidly

Indicates a Customer Doubler Unit (CDU) loopback is in effect in
the HDU-409 towards the customer. This tests the integrity of the
downstream span.

Flashing Green about
once per second

Indicates synchronization is being attempted between the
HDU-409 and the upstream (network) module.

Flashing Green rapidly

Indicates synchronization is being attempted between the
HDU-409 and the downstream (customer) module.

Steady Yellow

Indicates the HDSL margin is less than the margin threshold
provisioned for the circuit.

Steady Green

Indicates HDSL frame synchronization has been achieved
between the HDU-409 and both the upstream and downstream
modules.

Advertising