Alternative doubler enclosure capacities – ADC and 3 Doubler User Manual

Page 22

Advertising
background image

Generic Information

LTPH-UM-1234-01

16

April 30, 2003

HDU-409 Lists 1, 2, and 3

A

LTERNATIVE

D

OUBLER

E

NCLOSURE

C

APACITIES

Reduce the doubler capacity by one for every two doublers that do not have
an empty slot between them. If the application allows seven doublers, but two
are directly adjacent to each other, then the total capacity must be reduced to
six.

Standard T1 or LD1 repeaters can be installed in the same enclosure with
doubler units. If this method is used, the maximum number of doublers that
can occupy the same case with the standard repeaters must be reduced by one
for every four T1 or LD1 repeaters (or fractions thereof) installed.

Rule one on

page 11

, in the section titled,

“Doubler Enclosure

Capacities with Full Solar Load” on page 9

, does not apply if

the adjacent slot is occupied by a T1 or LD1 repeater;
however, slots adjacent to doublers should be left vacant if
possible.