Mixing higain doublers, Micro doubler capacity deployment rules – ADC and 3 Doubler User Manual

Page 24

Advertising
background image

Generic Information

LTPH-UM-1234-01

18

April 30, 2003

HDU-409 Lists 1, 2, and 3

M

IXING

H

I

G

AIN

D

OUBLERS

The HiGain HDU-439 mini doubler can also be installed along with the
HDU-409 micro doubler in the same enclosure. Assign a thermal weight of
1.5 HDU-409 for every HDU-439 and round down to the nearest whole
number. This results in one of the following thermal relationships:

a) 1.5 (HDU-409) = 1 (HDU-439)

b) 1 (HDU-409) = 2/3 (HDU-439)

For example, if an AT&T 819 case has only 10 HDU-409 doublers leaving
room for four more HDU-409 doublers, the number of HDU-439 doublers
that can be allotted to these 4 slots is determined by using (b) as follows:

4 (HDU-409) = (4) (2/3) (HDU-439)

4 (HDU-409) = 2.66 (HDU-439) = 2 (HDU-439)

Similarly the number of HDU-439 doublers that can be allotted to 6 empty
HDU-409 slots is:

6 (HDU-409) = (6) (2/3) (HDU-439) = 3 (HDU-439)

M

ICRO

D

OUBLER

C

APACITY

D

EPLOYMENT

R

ULES

The deployment rules for micro doubler capacity are summarized below:

1

Use

Table 4 on page 11

for indoor enclosures.

2

Use

Table 5

and

Table 6 on page 15

for outdoor enclosures with full

solar load for ambient temperatures up to 115°F maximum.

3

The capacities shown in

Table 5

can be increased to all odd or even slots

(where applicable) for non-solar load (shaded or manhole applications).
The non-adjacency constraint still applies for these increased capacity
applications. The capacity of the ABACON HDSL 16 enclosure can be
increased to 16 for non-solar load applications.

When assigning slot locations, make sure there is an empty
slot between any two adjacent doublers (HDU-409 and
HDU-439).